BZQWD - MAGNESIUM NITRATE HEXAHYDRATE
- MSDS: BZQWD
- Manufacturer: SPECTRUM CHEMICAL MFG CORP
- Product Name: MAGNESIUM NITRATE HEXAHYDRATE
- National Stock Number: 6810-00-264-8963
Product Identification
Product ID:MAGNESIUM NITRATE HEXAHYDRATE
MSDS Date:06/23/1999
FSC:6810
NIIN:00-264-8963
MSDS Number: BZQWD
Responsible Party
GARDENA, CA 90248-2027
US
Emergency Phone: 310-516-8000
Info Phone: 310-516-8000
Preparer: G.A.BINAS
Cage: 63415
Contractor
Telephone: 916-941-3688
Cage: 1KH20
Ingredients
MAGNESIUM NITRATE,HEXAHYDRATE
CAS: 13446-18-9
RTECS: OM3756000
Hazards
LD50 LC50 Mixture:NOT AVAILABLE
Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: NO SPECIFIC INFORMATION
AVAILABLE IN MFR DATABASE REGARDING TOXIC EFFECTS OF MATERIAL. MAY
CAUSE SLIGHT SKIN AND EYE IRRITATION ON CONTACT. MAY CAUSE SLIGHT
RESPIRATORY IRRITATION IF DUST INHAL ED. CHRONIC: REPEATED OR
PROLONGED EXPOSURE TO PRODUCT CAN PRODUCE TARGET ORGAN DAMAGE.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
SKIN-IRRITATION. EYES-IRRITATION. INHALED-RESPIRATORY IRRITATION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHALATION: ALLOW THE VICTIM REST IN WELL VENTILATED AREA.
SEEK IMMEDIATE MEDICAL ATTENTION. EYE CONTACT: CHECK FOR AND REMOVE
ANY CONTACT LENSES. IMMEDIATELY FLUSH EYES WITH RUNNING WATER FOR
AT LEAS T 15 MINUTES, KEEPING EYELIDS OPEN. SEEKMEDICAL ATTENTION.
SKIN CONTACT: WASH SKIN THOROUGHLY WITH NON-ABRASIVE SOAP AND
WATER. IF IRRITATION PERSISTS, CONSULT A PHYSICIAN. INGESTION: DO
NOT INDUCE VO MITING. LOOSEN TIGHT CLOTHING SUCH AS A COLLAR, TIE,
OR BELT. IF THE VICTIM IS NOT BREATHING, PERFORM MOUTH-TO-MOUTH
RESUSCITATION. SEEK IMMEDIATE MEDICAL ATTENTION.
Fire Fighting
Extinguishing Media:DO NOT USE WATER JET. USE FLOODING QUANTITIES OF
WATER.
Fire Fighting Procedures:NONE SPECIFIED BY MANUFACTURER. DLA-HMIS: WEAR
SELF-CONTAINED BREATHING APPARATUS AND FULL FIRE FIGHTER'S
PROTECTIVE GEAR.
Unusual Fire/Explosion Hazard:SLIGHTLY FLAMMABLE TO FLAMMABLE IN
PRESENCE OF REDUCING MATERIALS. NO SPECIFIC INFORMATION AVAILABLE
IN MFR DATABSE REGARDING PRODUCTS RISKS OF EXPLOSION.
Accidental Release
Spill Release Procedures:USE APPROPRIATE TOOLS TO PUT THE SPILLED SOLID
INTO A CONVENIENT WASTE DISPOSAL CONTAINER. FINISH CLEANING BY
SPREADING WATER ON THE CONTAMINATED SURFACE AND DISPOSE OF IAW
LOCAL, STATE AND FEDERAL RE GULATIONS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN A COOL, DRY, WELL-VENTILATED
PLACE. GROUND ALL EQUIPMENT CONTAINING MATERIAL. KEEP CONTAINER
TIGHTLY CLOSED. KEEP AWAY FROM INCOMPATIBLES.
Other Precautions:EMPTY CONTAINERS POSE A FIRE RISK. DO NOT BREATH
DUST. AVOID CONTACT WITH SKIN & EYES.
Exposure Controls
Respiratory Protection:IF ENGINEERING CONTROLS FAIL OR NON-ROUTINE USE
OR AN EMERGENCY OCCURS; WEAR AN MSHA/NIOSH APPROVED RESPIRATOR WITH
DUST CARTRIDGE OR AN AIR-SUPPLIED RESPIRATOR OR SCBA, AS REQUIRED.
USE IAW 29 CFR 19 10.134.
Ventilation:USE ADEQUATE MECHANICAL VENTILATION OR LOCAL EXHAUST TO
MAINTAIN EXPOSURE BELOW TLV(S).
Protective Gloves:IMPERVIOUS-RUBBER, PVC, NITRILE.
Eye Protection:SAFETY GLASSES/CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:LAB COAT. DLA-HMIS: EYE WASH STATION &
SAFETY SHOWER.
Work Hygienic Practices:WASH HANDS AFTER HANDLING AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health
MSDS PRESENTED BY CAGE 0YED2 FOR CONTRACT NUMBER SP0450-96-ML608.
Chemical Properties
HCC:D1
Boiling Pt:B.P. Text:DECOMPOSES
Melt/Freeze Pt:=89.C, 192.2F
Spec Gravity:1.64
Evaporation Rate & Reference:NONE SPECIFIED BY MFR.
Solubility in Water:APPRECIABLE
Appearance and Odor:SOLID.
Stability
Stability Indicator/Materials to Avoid:YES
NO SPECIFIC INFORMATION AVAILABLE IN MFR'S DATABASE REGARDING
REACTIVITY OF MATERIAL IN PRESENCE OF OTHER MATERIALS.
Stability Condition to Avoid:NO ADDITIONAL REMARKS.
Hazardous Decomposition Products:SOME METALLIC OXIDES.
Disposal
Waste Disposal Methods:RECYCLE TO PROCESS IF POSSIBLE. DISPOSE OF IN
ACCORDANCE WITH LOCAL, STATE AND FEDERAL ENVIRONMENTAL REGULATIONS.
Toxicology
Toxicological Information:LD50 NOT AVAILABLE.
Regulatory
Federal Regulatory Information:THIS MATERIAL IS IN THE TOXIC SUBSTANCE
CONTROL ACT (TSCA) INVENTORY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.